in cast iron GG 25 or high grade steel. For incorporation in tanks. Also to deliver with hydraulic-oil tank to use for hydraulic station. Size of oil tank on inquiry.
Types in cast iron with circulation valve in pump lid possible (Type FAMU). Type FAM 1-017 until 219
and FAMU 15 until 219
Saug- und Druckanschl. suction- pressure connection
Motormaße motor-dimensions
Pumpenmaß pump-dimensions
Flansch-Laternen-Maße flange-latern-dimensions
Gewicht weight
A
B
øC
K
D
E
P
R
F
øG
H
M
m
N
O
1-017
0.12
20
0.25
G ¼"
337
176
124
9
36
35
75
10
90
110
13
M8
9
160
130
8.9
1-06
0.43
20
0.25
G ¼"
337
176
124
9
36
35
75
10
90
110
13
M8
9
160
130
8.9
15
0.85
50
0.25
G ¼"
337
176
124
9
36
35
75
10
90
110
13
M8
9
160
130
8.9
17
1.20
50
0.25
G ¼"
337
176
124
9
36
35
75
10
90
110
13
M8
9
160
130
8.9
110
1.80
40
0.25
G 3/8"
337
176
124
9
36
35
75
10
90
110
13
M8
9
160
130
8.9
110
1.80
50
0.37
G 3/8"
337
176
124
9
36
35
75
10
90
110
13
M8
9
160
130
9.9
210
2.30
30
0.25
G 3/8"
354
176
124
9
48
40
91
12
90
110
13
M8
9
160
130
9.8
210
2.30
40
0.37
G 3/8"
354
176
124
9
48
40
91
12
90
110
13
M8
9
160
130
10.8
210
2.30
70
0.55
G 3/8"
421
209
139
10
48
40
91
12
124
145
16
M10
11
200
165
14.2
214
3.20
20
0.25
G 3/8"
354
176
124
9
48
40
91
12
90
110
13
M8
9
160
130
9.8
214
3.20
30
0.37
G 3/8"
354
176
124
9
48
40
91
12
90
110
13
M8
9
160
130
10.8
214
3.20
40
0.55
G 3/8"
421
209
139
10
48
40
91
12
124
145
16
M10
11
200
165
14.2
214
3.20
60
0.75
G 3/8"
421
209
139
10
48
40
91
12
124
145
16
M10
11
200
165
15.3
214
3.20
70
1.1
G 3/8"
404
226
157
10
48
40
91
12
90
145
16
M10
11
200
165
19.1
219
4.30
15
0.25
G ½"
354
176
124
9
48
40
91
12
90
110
13
M8
9
160
130
9.8
219
4.30
20
0.37
G ½"
354
176
124
9
48
40
91
12
90
110
13
M8
9
160
130
10.8
219
4.30
30
0.55
G ½"
421
209
139
10
48
40
91
12
124
145
16
M10
11
200
165
14.2
219
4.30
40
0.75
G ½"
421
209
139
10
48
40
91
12
124
145
16
M10
11
200
165
15.3
219
4.30
60
1.1
G ½"
404
226
157
10
48
40
91
12
90
145
16
M10
11
200
165
19.1
219
4.30
70
1.5
G ½"
426
248
157
10
48
40
91
12
90
145
16
M10
11
200
165
21.6
U = Circulation valve in pump lid. Max pressure adjustable 20 bar.
Standard direction of power shaft: right. Left rotation on inquiry.
Motor data: 1450 min-1, single-phase motor 230 V (max. 1,5 kW) or three-phase motor 230/400 V and/or 400/690 V, 50 Hz Other driving motors and/or power rating on inquiry.