Gear Pumps        Rotor Pumps        Centrifugal Pumps        Impeller Pumps        Service/Spare Parts  
 
Linn-Pumpen GmbH
Homepage        Linn-Pumpen        Contact        Impressum/AGB's   
select your language
 english  german
 
NM
NM / NMD
NM4
C / NC
T / TP
MXH
CO
CEA / CA
SAL
Type A
SAL
CA
NG
BG
MXA
PAS
DOC
Domo
Diwa
WGP
Scuba
GS
L3
SSV
SVI
MP
SP
SPV
IMM
EPC
AP
VT
   
NG
download pdf data sheet
E-Mail: service@linn-pumpen.de
Phone: +49 (0)2355-902929
Type NG


Self-Priming Jet Pumps

Construction

Close-coupled self-priming shallow well jet pumps with built-in ejector.

Applications
For drawing water out of a well.
As pressure boosting pump for central water systems with low pressure (follow local specifications if increasing network pressure).
For clean liquods or slightly dirty surface water.
For garden use.
For washing with a jet of water.

Operating conditions

Liquid temparature up to 40°C.
Ambient temparature up to 40°C.
Maximum permissible working pressure up to 10 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n= 290 rpm).
NG: three-phase 230/400V ± 10%
NGM: single-phase 230V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60335-2-41.

Special features on request
- other voltages.
- Frequency 60 Hz.
- Protection IP 55.
- Special mechanical seal
- Higher liquid or ambient temparatures.

Materials
Components NG B-NG
Pump casing
Cover with latern bracket
Diffuser plate
Cast iron
GJL 200 EN 1561
Bronze
B-Cu Sn 10 UNI 7013
ImpellerBrass P-Cu Zn 40 Pb 2 UNI 5705
Shaft Chrome steel
1.4104 EN 10088
AISI 420
Chrome-nickle steel
1.44.1 EN 10088
AISI 316
Diffuser
Ejector
Polycarbonate
Mechanical sealCarbon - Ceramic -NBR
Performance (2850 min-¹, 50 Hz)


Characteristic Curves for suction lift Hs = 1m,

Characteristic Curves Type NG



3~ 230V 400V
1~ 230V P1
P2
Q
m³/h
0,25
0,5
1
1,5
2
2,5
3
3,5
4
4,5
5
5,5
6
6,5
7
8
9
9,5
...................
A
A
..............................
A
kW
kW
HP
l/min
4,1
8,3
16,6
25
33,3
41,6
50
58,3
66,6
75
83,3
91,6
100
108
116
133
150
158
NG 3E
B-NG 3E
3
1,7
NGM 3E
B-NGM 3E
4,5
0,9
0,55
0,75
H
(m)
49
45,5
40
36
32
28
24
-
-
-
-
-
-
-
-
-
-
-
NG 4E
B -NG 4E
3,7
2,2
NGM 4E
B -NGM 4E
5,7
1
0,75
1
41
39
36
33
31
29
26
24
21
-
-
-
-
-
-
-
-
-
B-NG 5/16E
5
2,9
B-NGM 5/16E
7,4
1,64
1,1
1,5
-
59
54
50
46
43
40
37
34,5
32
-
-
-
-
-
-
-
-
B-NG 5/18E
5
2,9
B-NGM 5/18E
7,4
1,68
1,1
1,5
-
48,5
46
43,5
41,5
39,5
38
35,5
34
32
30,5
29
28
-
-
-
-
-
B-NG 5/22E
5
2,9
B-NGM 5/22E
7,4
1,55
1,1
1,5
-
35,5
34,5
33
31,5
30,5
29,5
28
27
26
25
23,5
23
21,5
20,5
18,5
16,5
15,5
B-NG 6/18E
7,5
4,3
-
-
-
1,5
2
-
64,5
62
59
56
54
51
48,5
46
43,5
41,5
39
36,5
-
-
-
-
-
-
-
-
B-NGM 6/16E
9,2
2
1,5
2
-
59
57
54
51
48
45
43
40
37,5
35
33
30
-
-
-
-
-
B-NG 6/22E
7,5
4,3
-
-
-
1,5
2
-
51,5
50
48,5
47
46
44,5
43
41,5
40
39
37,5
36,5
35
33,5
31
28,5
27
-
-
-
B-NGM 6/22E
9,2
2
1,5
2
-
47
45
43,5
42
41
40
38
37
36
35
33
32
31
30
27
24
23
B-NG 7/16E
9,15
5,3
-
-
-
2,2
3
-
89
83
77
72
67
62
58
54
-
-
-
-
-
-
-
-
-
B-NG 7/18E
9,15
5,3
-
-
-
2,2
3
-
74,5
71,5
68,5
65,5
63
60
57,5
55
53
51
49
47
45
-
-
-
-
B-NG 7/22E
9,15
5,3
-
-
-
2,2
3
-
59
57,5
56,5
55
54
52,5
51
50
48,5
47
45,5
44
42,5
41,5
38
35
34
P1 Max. power input
P2 Rated motor power output
B-NG, B-NGM = Bronze construction.
Tolerances according to ISO 9906, annex A.
Installation examples
Positive suction head operation
Type NG
Suction lift operation Type NG
Dimensions and weights

Type NG

TYPE
DN1
DN2
mm
kg
ISO 228
a1
a2
f
h1
h2
h3
m1
m2
m3
n1
n2
b
s
w
g
NG
B-NG
NG 3E
NG 4E
B-NG 3E
B-NG 4E
G1
G1
127
8
430
150
43
203
60
52
8
185
155
35
9,5
100
11
18,4
19,2
20,8
21,5
NG 5E
NG 6E
NG 7E
B-NG 5E
B-NG 6E
B-NG 7E
G1½
G1
160
10
560
165
57
197
60
50
10
215
175
40
11,5
115
11
29,2
30,8
31,3
31,6
32,9
33,4
notice 

Subject to change!
     
 Linn-Pumpen GmbH • Gewerbering 15 • D-58579 Schalksmühle • Tel. +49 (0) 23 55 - 90 29 29 • Fax +49 (0) 23 55 - 90 29 99