type DB 13 - BD 40
The DB pressure relief valves are direct-controled piston
valves. If the preset pressure is exceeded, it opens and
feeds the medium back into the tank via a bypass pipe
(leakage pipe).
Installation
Pressure relief valves series DB must be installed in an
upright position. The valve will be installed in the discharge
pipe with a bypass line. The bypass pipe at the outlet of the
valve is returned pressureless to the tank.
Fluids: Oils up to a viscosity of 350 mm²/sec (special design on request)
Installation scheme
Size | R" Thread |
Dimensions | |||||
---|---|---|---|---|---|---|---|
A | B | C | D | E | M | ||
DB 13 | ½" | 35 | 42 | 100 | 38 | 58 | M40x1,5 |
DB 20 | ¾" | 45 | 47 | 100 | 45 | 58 | M40x1,5 |
DB 25 | 1" | 50 | 55 | 120 | 55 | 72 | M52x1,5 |
DB 40 | 1½" | 65 | 70 | 135 | 70 | 90 | M70x2 |
Size | Range of pressure (bar) from - to |
Flow (l/min) under pressure of (bar) | |||||
---|---|---|---|---|---|---|---|
2 | 50 | 120 | |||||
DB 13 | 2-10 | 10-35 | 35-120 | - | 25 | 50 | 80 |
DB 20 | 2-10 | 10-35 | 35-120 | - | 33 | 70 | 100 |
DB 25 | 2-5 | 5-25 | 25-60 | 50-100 | 45 | 100 | 150 |
DB 40 | 2-5 | 5-10 | 10-60 | 40-100 | 60 | 170 | 250 |
Subject to change!
Die Firma Linn-Pumpen GmbH übernimmt keine Haftung für Folgeschäden, welche aus evtl. fehlerhaften Informationen resultieren.