MXS Stainless steel submersible pump - cistern pump- fountain pump

Close coupled multi-stage submersible pumps. All parts in contact with the fluid both internal and external are in chrome-nickle stainless steel. MXSM with built-in capacitor, accessible through the delivery casing. Hydraulics located below the motor with the motor cooled by the pumped fluid. Safe operation is possible with the motor only partially submerged. Double shaft seal with oil chamber. the suction strainer prevents the entrance of solids with diameter bigger than 2 mm.

Applications
For water supply from wells, tanks or reservoirs. For domestic, civil and industrial applications, for garden use, irrigation and rain water harvesting systems.

Operating conditions
Water temperature up to 35 °C.
Minimum internal diameter of well: 140 mm.
Minimum immersion depth: 100 mm.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n ≈ 2900 1/min).
MXS : three-phase 230 V ± 10%; three-phase 400 V ± 10%. Cable: H07Rn8-F, length 15 m, without plug.
MXSM: single-phase 230 V ± 10%, with thermal protector. Incorporated capacitor. Float switch MXSM.. CG up to 10a (on demand)
Cable: H07Rn8-F, length 15 m, with plug CEI-UNEL 47166.
Insulation class F.
protection Ip 68 (for continuous immersion).
Double impregnation humidity-proof dry winding.
Constructed in accordance with en 60335-2-41.

Special features on request
- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
- Cable length 20 m.
- Motor suitable operation with frequency converter.


Materials

Component Material
Delivery casing
external jacket
Suction strainer
Stage casing
Spacer sleeve
Impeller
Motor jacket
Jacket cover
Oil chamber cover
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Shaft Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Upper mechanical seal
Lower mechanical seal
Steatite, carbon, NBR
Ceramic alumina, silicon carbide, NBR
Seal lubrication oil Oil for food machinery and pharmaceutic use

Performance ( n ≈ 2900 1/min )

3 ~ 1 ~ Capacitor P1 P2 Delivery
m³/h  0 1 1,5 2 2,5 3 3,5 4 4,5
230 V 400V 230V l/min  0 16,6 25 33,3 41,6 50 58,3 66,6 75
A A A µF V kW kW HP total head in metres column of water
MXS 303  2,4 1,4 MXSM 303  3,5 14 450 0,8 0,45 0,6 32,5 29,5 27,5 25,5 23 19,5 17 13 10
MXS 304  2,8 1,6 MXSM 304  4,1 20 450 0,9 0,55 0,75 44 41,5 39,5 36,5 33,5 29,5 25,5 21 16
MXS 305  3,3 1,9 MXSM 305  5 20 450 1,1 0,75 1 53 49,5 47 44 40 35 30 25 19
MXS 306  3,8 2,2 MXSM 306  6 25 450 1,3 0,9 1,2 65 61 58 54 49 43 37 30,5 23
MXS 307  4,5 2,6 MXSM 307  6,6 25 450 1,5 0,9 1,2 77,5 71 66,5 61 55 49 42 35 27
MXS 308  4,8 2,8 MXSM 308  8,3 30 450 1,7 1,1 1,5 88,5 81,5 76 70,5 64 56,5 49,5 41 32
MXS 309  6,6 3,8 MXSM 309  9 30 450 1,9 1,5 2 100 91 85 78,5 70,5 62,5 54,4 45 35
MXS 310  7,5 4,3 MXSM 310  12 35 450 2,2 1,5 2 111 101,5 95 88,5 80 71 62 52,5 41,5
P1 Max. Imput power. P2 Rated motor power output tolerances according to UnI en ISO 9906:2012
test results with clean cold water, without gas content.

3 ~ 1 ~ capacitor P1 P2 Delivery
m³/h  0 2,5 3 3,5 4 4,5 6 6 7 8
230 V 400V 230V l/min  0 41,6 50 58,3 66,6 75 83,3 100 116 133
A A A µF V kW kW HP total head in metres column of water
MXS 503  2,8 1,6 MXSM 503  4,1 20 450 0,9 0,55 0,75 32,2 28,5 27,5 26 24,5 22,5 21,5 18 13,5 8
MXS 504  3,8 2,2 MXSM 504  6 25 450 1,2 0,9 1,2 43 39 38 36,5 34,5 33 30,5 25,5 19,5 13
MXS 505  4,5 2,6 MXSM 505  7 25 450 1,5 1,1 1,5 53 47,5 45,5 43,5 41 38,5 35,5 29,5 22 13,5
MXS 506  4,8 2,8 MXSM 506  8,3 30 450 1,7 1,1 1,5 66,5 58 55,6 53,5 51 48 45 36,5 27,5 16
MXS 507  6,8 3,9 MXSM 507  12 35 450 2,2 1,5 2 78,5 69,5 66,5 64 61,5 58 54,5 45,5 36 22
MXS 508  7,5 4,3 MXSM 508  13 35 450 2,4 1,5 2 88,5 78 75 72 68 64 60 50 38 25
MXS 509  9,7 5,6 MXSM 509  14,3 40 450 2,9 2,2 3 101 91 87,5 84 80,5 75,5 71 60 46,5 28,5
MXS 510  9,7 5,6   2,2 3 113 101 98,5 95 92 87,5 83 71,5 56 35
P1 Max. Imput power. P2 Rated motor power output tolerances according to UnI en ISO 9906:2012
test results with clean cold water, without gas content.

3 ~ 1 ~ Capacitor P1 P2 Delivery
m³/h  0 5 6 7 8 9 10 11
230 V 400V 230V l/min  0 83,3 100 116 133 150 166,6 183,3
A A A µF V kW kW HP total head in metres column of water
MXS 903  4,5 2,6 MXSM 903  7 25 450 1,5 1,1 1,5 34,5 29,5 28 26,5 24,5 22,5 20 16,5
MXS 904  6,6 3,8 MXSM 904  9 30 450 1,9 1,5 2 45,5 39 37 35 32,5 30 26,5 22,5
MXS 905  7,5 4,3 MXSM 905  13 35 450 2,4 2,2 3 58 49 46,5 45 42,5 38,5 34 30
MXS 906  9,7 5,6 MXSM 906  14,3 40 450 2,9 2,2 3 70 59,5 56,5 54 50,5 46,5 42 37
MXS 907  11,4 6,6 3 4 81 71 68,5 66 62 58 53 47
MXS 908  17,7 8,5 3 4 93 81 78 75 71 66 60,5 53
MXS 909  17,7 8,5 3 4 105 92 88 84 79 73,5 67,5 57,5
MXS 910  17,7 8,5 3 4 117 101,2 96,5 93 87,5 81,5 73,5 63,5
P1 Max. Imput power. P2 Rated motor power output tolerances according to UnI en ISO 9906:2012
test results with clean cold water, without gas content.

Dimensions and weight

Weights with cable length: 15 m
pump H kg cable H07RN8-F
mm MXS MXSM 230V 1-phase 230V 3-phase 400V 3-phase
MXS 303 MXSM 303  465 12,5 13,5 3G1 mm2  4G1 mm2  4G1 mm2 
MXS 304 MXSM 304  504 14,5 15,5 3G1 mm2  4G1 mm2  4G1 mm2 
MXS 305 MXSM 305  553 15 16,5 3G1 mm2  4G1 mm2  4G1 mm2 
MXS 306 MXSM 306  577 15,5 17 3G1 mm2  4G1 mm2  4G1 mm2 
MXS 307 MXSM 307  601 16 17,5 3G1 mm2  4G1 mm2  4G1 mm2 
MXS 308 MXSM 308  671 18,5 19,5 3G1,5 mm2  4G1 mm2  4G1 mm2 
MXS 309 MXSM 309  695 20,6 21,6 3G1,5 mm2  4G1,5 mm2  4G1 mm2 
MXS 310 MXSM 310  744 23 25,1 3G2,5 mm2  4G1,5 mm2  4G1 mm2 
MXS 503 MXSM 503  480 14,5 15,5 3G1 mm2  4G1 mm2  4G1 mm2 
MXS 504 MXSM 504  529 15 16 3G1 mm2  4G1 mm2  4G1 mm2 
MXS 505 MXSM 505  553 16,1 17,6 3G1 mm2  4G1 mm2  4G1 mm2 
MXS 506 MXSM 506  622 17,5 19 3G1,5 mm2  4G1 mm2  4G1 mm2 
MXS 507 MXSM 507  671 20 21,5 3G2,5 mm2  4G1 mm2  4G1 mm2 
MXS 508 MXSM 508  695 20,5 22 3G2,5 mm2  4G1,5 mm2  4G1 mm2 
MXS 509 MXSM 509  744 23 24,5 3G2,5 mm2  4G1,5 mm2  4G1 mm2 
MXS 510    768 27 4G1,5 mm2  4G1 mm2 
MXS 903 MXSM 903  523 16,1 17,6 3G1,5 mm2  4G1 mm2  4G1 mm2 
MXS 904 MXSM 904  573 18,2 19,7 3G1,5 mm2  4G1 mm2  4G1 mm2 
MXS 905 MXSM 905  653 19 22 3G1,5 mm2  4G1,5 mm2  4G1 mm2 
MXS 906 MXSM 906  708 23 26 3G2,5 mm2  4G1,5 mm2  4G1 mm2 
MXS 907    738 26,3 4G2,5 mm2  4G1 mm2 
MXS 908    793 27   4G2,5 mm2  4G1 mm2 
MXS 909    823 28,1   4G2,5 mm2  4G1,5 mm2 
MXS 910    853 29,5   4G2,5 mm2  4G1,5 mm2 

MXSM ... CG with float switch pump (on demand)

GXR Tauchmotorpumpe Abmessungen

Installation

pump in suspended position Tauchpumpe mit Schwimmerschalter Einbauschema
pump with float switch (on demand) Brunnenpumpe Brunneneinbau Schema 
Installation example Zisternenpumpe - Zisterneneinbau - Tankeinbau Schema